- Other Lights & Lighting Products[9]
- Other Solar Energy Related Products[10]
- Inverters & Converters[7]
- Solar Chargers[1]
- Backpacks[3]
- Laptop Bags[3]
- Rechargeable Batteries[3]
- Chargers[1]
- Solar Energy Systems[7]
- Mobile Phone Chargers[1]
- Tents[2]
- Camping Lights[1]
- Road Stud[7]
- Flashlights & Torches[7]
- Garden Lights[6]
- Underground Lamps[1]
- Plastic Flooring[7]
- Plastic Product Making Machinery[10]
- Other Plastic Processing Machinery[4]
- Plastic Recycling Machinery[2]
- Contact Person : Mr. Bin Zhang
- Company Name : Zhangjiagang Glory Trading Co., Ltd.
- Tel : 86-512-56796581,13862203958
- Fax : 86-512-56796582
- Address : Jiangsu,ZHANGJIAGANG,11F.,Xindu Masion,Yangshe Town,Zhangjiagang City
- Country/Region : China
800W Pure sine wave Grid Tie Inverter
800W Pure sine wave Grid Tie Inverter
A.System Function
1,directly connected to the solar panels (do not need to connect the battery)
2,AC 0 angle with high precision auto-detection
Pure Sine Wave Output
3,Automatic Sensing Function Solar Luminosity
Power Automatically Locked (APL)
Maximum Power Point Tracking (MPPT)
Automatically Adapt To Different Load Power Factor
4,Constant Current, Constant Power
5, Current Limit Protection
6,Stack Multiple Machines
7,High-Frequency High Conversion Rate
B.Specification:
Grid-series models | GSS-GTI-006 |
Recommend use solar panels | 1050Wp |
DC Maximum Input Power | 900W |
DC maximum voltage | VpvDC30.2VDC |
DC voltage range | Vpv 10.5V~28VDC |
Maximum output power factor | 99% |
Maximum input current | 45A |
AC output power | 800W |
AC maximum output power | 1000W |
Anti-voltage protection | Fuse |
AC standard voltage range | 90V-140/180~260VAC |
AC frequency range | 55Hz~63Hz/ 45Hz-53Hz |
Output current total harmonic distortion | THDIAC <5% |
Phase | <1% |
Islanding protection | VAC;f AC |
Output short circuit protection | Current-limiting |
Show | LED |
Installation | Wall hanging |
Cooling | Fan |
Standby Power | <2W |
Night Power | <1W |
Ambient temperature range | -25 °C~60°C |
Humidity | 0~99%(Indoor Type Design) |
Waterproof | Indoor Type Design |
Electromagnetic Compatibility | EN50081.part1 EN50082.part1 |
Power System Disturbance | EN61000-3-2 EN60950-1 |
Network test | DIN VDE 1026 |
N.W | 2.0kg |
G.W | 2.5kg |
Size (L x W x H) | 31 x 16.5 x 5.5cm |
Packing (L x W x H) cm | Inner box: 39 x 20.3 x 11.3 Outer box: 42x31.5x36.5 |
AC Power Cord | 1.8 m |
Input and output
1,DC input
* Input voltage range: 10.5V to 28V.
* Solar Panel: recommend the use of power greater than 30W, the standard voltage 17.5V PV panels.
* Recommended, and even solar panels, thread will result in high input voltage inverter which exceeds the working voltage range.
* Wind turbine: Rated voltage 24VDC, maximum voltage 28VDC.
2,AC output:
* Output 220V AC power inverter can be used in voltage: 170V - 260V, 50 Hz
* Output 110V AC power inverter can be used in voltage range: 90V - 160V, 60 Hz
LED Indicator:
1,Red LED:
* Low-voltage protection (input DC voltage is less than 10.5VDC).
* Overvoltage protection (Input DC voltage is greater than 28.5VDC).
* Over-temperature protection (when the chassis temperature is above 75 °C,
the temperature dropped about 2-10 minutes to restart automatically after cooling).
* Fault Protection (when 110VAC or 220VAC power outage or shutdown).
* Islanding protection: electricity disconnected, the inverter automatically shut down output.
2,Green LED:
* Green LED flashing: are adjusting power output, MPPT is working condition.
* Long bright green LED: Indicates the maximum inverter output power is in the locked state of work.
Notes---Non-professionals do not disassemble, Only qualified personnel may repair this product.
---Please inverter installed in the low humidity and well-ventilated place to avoid the inverter
overheating, and clear around the inflammable and explosive materials.
---When using this product, avoid touching children, playing, to avoid electric shock.
---Recommended Maximum DC input 4AWG cable capable of handling more than 50A of the
cable size.
---Optimal length of the DC input line 8M or less, long cable will allow solar panels to the inverter
DC voltage drop caused by wear and tear.
---Connected to a power outlet to provide AC.
---Connected solar panels, battery or wind generators DC input DC power supply cable.---Proposed wind power plant with its own charge controller and load dump.
Input and output
1,DC input
* Input voltage range: 10.5V to 28V.
* Solar Panel: recommend the use of power greater than 30W, the standard voltage 17.5V PV panels.
* Recommended, and even solar panels, thread will result in high input voltage inverter which exceeds the working voltage range.
* Wind turbine: Rated voltage 24VDC, maximum voltage 28VDC.
2,AC output:
* Output 220V AC power inverter can be used in voltage: 170V - 260V, 50 Hz
* Output 110V AC power inverter can be used in voltage range: 90V - 160V, 60 Hz
LED Indicator:
1,Red LED:
* Low-voltage protection (input DC voltage is less than 10.5VDC).
* Overvoltage protection (Input DC voltage is greater than 28.5VDC).
* Over-temperature protection (when the chassis temperature is above 75 °C,
the temperature dropped about 2-10 minutes to restart automatically after cooling).
* Fault Protection (when 110VAC or 220VAC power outage or shutdown).
* Islanding protection: electricity disconnected, the inverter automatically shut down output.
2,Green LED:
* Green LED flashing: are adjusting power output, MPPT is working condition.
* Long bright green LED: Indicates the maximum inverter output power is in the locked state of work.
Notes
---Non-professionals do not disassemble, Only qualified personnel may repair this product.
---Please inverter installed in the low humidity and well-ventilated place to avoid the inverter
overheating, and clear around the inflammable and explosive materials.
---When using this product, avoid touching children, playing, to avoid electric shock.
---Recommended Maximum DC input 4AWG cable capable of handling more than 50A of the
cable size.
---Optimal length of the DC input line 8M or less, long cable will allow solar panels to the inverter
DC voltage drop caused by wear and tear.
---Connected to a power outlet to provide AC.
---Connected solar panels, battery or wind generators DC input DC power supply cable.---Proposed wind power plant with its own charge controller and load dump.
800W Pure sine wave Grid Tie Inverter